6 feet from the edge.
Roof edge fall protection requirements.
Between 6 feet and 15 feet from the edge.
Each employee on a walking working surface horizontal and vertical surface with an unprotected side or edge which is 6 feet 1 8 m or more above a lower level shall be protected from falling by the use of guardrail systems safety net systems or personal fall arrest systems.
I believe the misconception of a specific safe distance has surfaced since warning line rules require setbacks from the edge at 6 10 or 15 feet depending on the circumstances.
Conventional fall protection guardrail fall restraint or fall arrest system is required.
The use of a fall protection system is not required for a repair pit service pit or assembly pit that is less than 10 feet 3 m deep provided the employer.
Employers are to ensure.
The guard shall extend not less than 30.
Unprotected sides and edges.
Implement safe work practices to reduce the possibility of falls.
1910 28 b 8 i limits access within 6 feet 1 8 m of the edge of the pit to authorized employees trained in accordance with 1910 30.
Conventional fall protection guardrail fall restraint or.
Osha defines what fall protection is required based on how close employees are to the edge of the roof.
Supervise workers to ensure fall.
Understand the requirements of osha s fall protection standards at 29 cfr 1926 subpart m to protect workers exposed to falls six feet or more above a lower level.
For general industry working at a 4 foot height or a low sloped roof osha requires.
For work more than 15 feet from a roof edge the new rule states that the employer is not required to provide any fall protection provided the work is both infrequent and temporary.
In addition the code continues to specifically address fall protection near mechanical equipment which is where the edge accufit safety railing was being placed to protect requirements stating guards shall be provided where various components that require service are located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches 762mm above the floor roof or grade below.
Employers are to ensure that each employee is protected from falling by using fall.
Between 6 feet and 15 feet from the roof edge.
1910 28 b 8 ii.
Each employee on a steep roof with unprotected sides and edges 6 feet 1 8 m or more above lower levels shall be protected from falling by guardrail systems with toeboards safety net systems or personal fall arrest systems.